防火卷簾門安裝維修后需及時進(jìn)行功能測試

來源:http://m.luoboyy.com/  發(fā)布時間:2022-07-07 17:34:18

1、通電功能測試:將防火定州祈諾卷簾控制器分別與消防控制室的火災(zāi)報警控制器或消防聯(lián)動控制設(shè)備、相關(guān)的火災(zāi)探測器、卷門機(jī)等連接并通電,防火卷簾控制器應(yīng)處于正常工作狀態(tài);
1. Power on function test: connect and power on the fire prevention Dingzhou Qinuo roller shutter controller with the fire alarm controller or fire linkage control equipment in the fire control room, relevant fire detectors, door rolling machine, etc., and the fire prevention roller shutter controller should be in normal working state;
2、備用電源測試:設(shè)有備用電源的防火卷簾,其控制器應(yīng)有主、備電源轉(zhuǎn)換功能。備用電源的電池容量應(yīng)保證防火卷簾控制器在備用電源供電條件下能正??煽抗ぷ?h,并應(yīng)提供控制器控制卷門機(jī)速放控制裝置完成卷簾自重垂降,控制卷簾降下限位所需的電源;
2. Test of standby power supply: the controller of the fire shutter with standby power supply shall have the function of switching between main and standby power supply. The battery capacity of the standby power supply shall ensure that the fire shutter controller can work normally and reliably for 1H under the power supply condition of the standby power supply, and the power supply required for the controller to control the quick release control device of the door rolling machine to complete the self weight sag of the shutter and control the shutter to the lower limit shall be provided;
3、火災(zāi)報警功能測試:防火卷簾控制器應(yīng)直接或間接的接收來自火災(zāi)探測器組發(fā)出的火災(zāi)報警信號,并應(yīng)發(fā)出聲、光報警信號;
3. Fire alarm function test: the fire shutter controller shall directly or indirectly receive the fire alarm signal from the fire detector group, and shall send audible and visual alarm signals;
4、故障報警功能測試:防火卷簾控制器的電源缺相或相序有誤,以及防火卷簾控制器與火災(zāi)探測器之間的連接線斷線或發(fā)生故障,防火卷簾控制器均應(yīng)發(fā)出故障報警信號;
4. Fault alarm function test: if the power supply of the fire shutter controller is out of phase or the phase sequence is wrong, and the connecting wire between the fire shutter controller and the fire detector is broken or malfunctioned, the fire shutter controller shall send out fault alarm signals;
濟(jì)南防火卷簾門安裝維修
5、自動控制功能調(diào)試:自動控制功能調(diào)試時,當(dāng)防火卷簾控制器接收到火災(zāi)報警信號后,應(yīng)輸出控制防火卷簾完成相應(yīng)動作的信號,并應(yīng)符合下列要求:
5. Automatic control function debugging: when the automatic control function debugging, when the fire shutter controller receives the fire alarm signal, it should output the signal to control the fire shutter to complete the corresponding action, and should meet the following requirements:
1)控制分隔防火分區(qū)的防火卷簾由上限位自動關(guān)閉全閉;
1) Control the fire shutter separating the fire compartment to close automatically from the upper limit to the full close;
2)防火卷簾控制器接到感煙火災(zāi)探測器的報警信號后,控制防火卷簾自動關(guān)閉中位(1.8m)處停止,接到感溫火災(zāi)探測器的報警信號后,繼續(xù)關(guān)閉全閉;
2) After receiving the alarm signal from the smoke fire detector, the fire shutter controller controls the fire shutter to automatically close to the middle position (1.8m) and stop. After receiving the alarm signal from the temperature fire detector, it continues to close to the full close;
3)防火卷簾半降、全降的動作狀態(tài)信號應(yīng)反饋到消防控制室
3) The action status signals of half lowering and full lowering of the fire shutter shall be fed back to the fire control room
6、手動控制功能測試:手動控制功能調(diào)試時,手動操作防火卷簾控制器上的按鈕和手動按鈕盒上的按鈕,可控制防火卷簾的上升、下降、停止;
6. Manual control function test: during manual control function commissioning, manually operate the button on the fire shutter controller and the button on the manual button box to control the rise, fall and stop of the fire shutter;
7、自重下降功能測試:自重下降功能調(diào)試時,應(yīng)將濟(jì)南防火卷簾門安裝維修機(jī)電源設(shè)置于故障狀態(tài),防火卷簾應(yīng)在防火卷簾控制器的控制下,依靠自重下降全閉。
7. Self weight lowering function test: during the self weight lowering function commissioning, the power supply of Jinan fire shutter door installation and maintenance machine should be set in the fault state, and the fire shutter should fall to fully closed by self weight under the control of the fire shutter controller.
以上就是問題解答的相關(guān)內(nèi)容了,希望能夠幫助到大家,如對這一問題還存在任何疑問,都?xì)g迎關(guān)注我們網(wǎng)站http://m.luoboyy.com并咨詢我們的工作人員,將竭誠為您服務(wù)。
The above is the relevant content of the question answer. I hope it can help you. If you still have any questions about this problem, you are welcome to follow our website http://m.luoboyy.com And consult our staff, will serve you wholeheartedly.